OK Flux 10.62 (Advanced Slag Release)

ESAB

OK Flux 10.62 (Advanced Slag Release)

The following items have been added to your list


x

Improved OK Flux 10.62 with excellent slag detachability and very strong grains. Creates very smooth weld beads, soft transitions to side walls and concave weld bead profiles. Can be used with high parameters and all SAW process variants such as Tandem, Twin, ICE, 3 or 4 wire process in every multi pass joint including narrow gap. The strong grains allow multiple recycling cycles and prolonged flux hopper refilling intervals. Disturbances during flux recycling and dust creation are minimized. Flux chemistry, mechanical values and classifications for flux and all combinations same as for OK Flux 10.62, thus with various wires for highest demands on impact properties, low temperature toughness, strength and CTOD-values. For Offshore constructions, pressure vessels, power generation, shipbuilding, pipe mills, civil constructions, transport industries, etc. Produces weld metal with hydrogen contents maximum 5 ml/100 g, in BlockPac (moisture protection) maximum 4 ml/100g.

View Video

BUY NOW


Welding Process

  • SAW - Submerged Arc Welding

Typical Weld Metal Analysis %

Chemical Composition
Al2O3+MnO C CaF2 CaO+MgO Mn Ni Si SiO2+TiO2
15 % - 25 % 40 % - - - 15 %
Typical Weld Metal Analysis %
OK Autrod 12.22 AC, 580 A, 29 V
- 0.10 % - - 0.95 % - 0.27 % -
OK Autrod 12.22 DC+, 580 A, 29 V
- 0.07 % - - 1.0 % - 0.30 % -
OK Autrod 12.40 AC, 580A, 29V
- 0.12 % - - 1.85 % - 0.10 % -
OK Autrod 12.40 DC+, 580A, 29V
- 0.08 % - - 1.9 % - 0.12 % -
OK Autrod 13.21 AC, 580A, 29V
- 0.08 % - - 0.95 % 0.9 % 0.22 % -
OK Autrod 13.21 DC+, 580A, 29V
- 0.06 % - - 1.0 % 0.9 % 0.25 % -
OK Autrod 13.49 AC, 580A, 29V
- 0.08 % - - 0.95 % 3.1 % 0.20 % -
OK Autrod 13.49 DC+, 580A, 29V
- 0.06 % - - 1.0 % 3.1 % 0.25 % -

Approvals

Society TÜV
Wire OK Autrod 12.24
Society BKI
Wire OK Autrod 12.24
Society TÜV
Wire OK Autrod 12.22
Society BKI
Wire OK Autrod 12.32
Society Class NK
Wire OK Autrod 12.22
Society CWB
Wire OK Autrod 12.22
Society DB
Wire OK Autrod 12.22
Society RS
Wire OK Autrod 12.22
Society RINA
Wire OK Autrod 12.22
Society PRS
Wire OK Autrod 12.22
Society BKI
Wire OK Autrod 12.22
Society TÜV
Wire OK Autrod 12.32
Society DB
Wire OK Autrod 12.32
Society BKI
Wire OK Autrod 13.27
Society TÜV
Wire OK Autrod 13.27
Society BKI
Wire OK Autrod 13.10 SC
Society TÜV
Wire OK Autrod 13.10 SC
Society DB
Wire OK Autrod 13.10 SC
Society BKI
Wire OK Autrod 13.20 SC
Society Class NK
Wire OK Autrod 12.32
Society CWB
Wire OK Autrod 12.32
Society RS
Wire OK Autrod 12.32
Society RINA
Wire OK Autrod 12.32
Society PRS
Wire OK Autrod 12.32
Society GL
Wire OK Autrod 12.32
Society DNV
Wire OK Autrod 12.32
Society Class NK
Wire OK Autrod 12.34
Society CWB
Wire OK Autrod 12.34
Society RS
Wire OK Autrod 12.34
Society RINA
Wire OK Autrod 12.34
Society PRS
Wire OK Autrod 12.34
Society TÜV
Wire OK Autrod 13.20 SC
Society Class NK
Wire OK Autrod 13.27
Society CWB
Wire OK Autrod 13.27
Society RS
Wire OK Autrod 13.27
Society RINA
Wire OK Autrod 13.27
Society PRS
Wire OK Autrod 13.27
Society DB
Wire OK Autrod 13.27
Society GL
Wire OK Autrod 13.27
Society DNV
Wire OK Autrod 13.27
Society TÜV
Wire OK Autrod 13.24
Society RS
Wire OK Autrod 13.24
Society RINA
Wire OK Autrod 13.24
Society Class NK
Wire OK Autrod 13.43
Society CWB
Wire OK Autrod 13.43
Society TÜV
Wire OK Autrod 13.43
Society RS
Wire OK Autrod 13.43
Society RINA
Wire OK Autrod 13.43
Society PRS
Wire OK Autrod 13.43
Society Class NK
Wire OK Tubrod 15.27S
Society TÜV
Wire OK Tubrod 15.27S
Society RS
Wire OK Tubrod 15.27S
Society RINA
Wire OK Tubrod 15.27S
Society PRS
Wire OK Tubrod 15.27S
Wire OK Autrod 12.40
Wire OK Autrod 13.21
Society Class NK
Wire OK Autrod 13.24
Society CWB
Wire OK Autrod 13.24
Society PRS
Wire OK Autrod 13.24
Wire OK Autrod 13.49
Society DNV
Wire OK Autrod 12.34
*Selected production units only. Please contact ESAB for more information. Visit esab.com to download specific flux/wire combination fact sheets for more details.

Approvals

Grade EN 13479
Society CE
Country PL
Grade RD 03-613-03
Society NAKS/HAKC
Grade 51.039.07
Society DB
Approvals are based on factory location. Please contact ESAB for more information.

Classifications

AWS - As Welded A5.17: F7A8-EH12K
AWS - PWHT A5.17: F7P8-EH12K
AWS/EN A5.17:EH12K/ 14171-A:S3Si
EN - As Welded 14171-A: S 46 6 FB S3Si
Wire OK Autrod 12.32
AWS - As Welded A5.23: F8A6-EA2-A2
AWS - PWHT A5.23: F8P6-EA2-A2
AWS/EN A5.23:EA2/ 14171-A:S2Mo; 24598-A:S S Mo
EN - As Welded 14171-A: S 46 4 FB S2Mo
Wire OK Autrod 12.24
AWS - As Welded A5.17: F7A8-EM12K
AWS - PWHT A5.17: F6P8-EM12K
AWS/EN A5.17:EM12K/ 14171-A:S2Si
EN - As Welded 14171-A: S 38 5 FB S2Si
Wire OK Autrod 12.22
AWS - As Welded A5.23: F8A6-EA4-A4
AWS - PWHT A5.23: F8P6-EA4-A4
AWS/EN A5.23:EA4/ 14171-A:S3Mo; 24598-A:S S MnMo
EN - As Welded 14171-A: S 50 4 FB S3Mo
Wire OK Autrod 12.34
AWS - As Welded A5.17: F7A6-EH14
AWS - PWHT A5.17: F7P6-EH14
AWS/EN A5.17:EH14/ 14171-A:S4
EN - As Welded 14171-A: S 50 4 FB S4
Wire OK Autrod 12.40
AWS - As Welded A5.23: F7A6-ENi1-Ni1
AWS - PWHT A5.23: F7P8-ENi1-Ni1
AWS/EN A5.23:ENi1/ 14171-A:S2Ni1
EN - As Welded 14171-A: S 42 4 FB S2Ni1
Wire OK Autrod 13.21
AWS - As Welded A5.23: F7A10-ENi2-Ni2
AWS - PWHT A5.23: F7P10-ENi2-Ni2
AWS/EN A5.23:ENi2/ 14171-A:S2Ni2
EN - As Welded 14171-A: S 46 7 FB S2Ni2
Wire OK Autrod 13.27
AWS - As Welded A5.23: F8A10-ENi6-Ni6
AWS - PWHT A5.23: F8P8-ENi6-Ni6
AWS/EN A5.23:ENi6/ 14171-A:S3Ni1Mo0,2
EN - As Welded 14171-A: S 50 6 FB S3Ni1Mo0.2
Wire OK Autrod 13.24
AWS - As Welded A5.23: F11A8-EG-G
AWS - PWHT A5.23: F11P8-EG-G
AWS/EN A5.23:EG/ 26304-A:S3Ni2,5CrMo; 26304-B:(SUN4C1M3)
EN - As Welded 26304-A: S 69 6 FB S3Ni2,5CrMo
Wire OK Autrod 13.43
AWS - As Welded A5.23: F10A8-EG-F3 (AC)
AWS - PWHT A5.23: F9P8-EG-F3
AWS/EN A5.23:EG/ 14171-A:S3Ni1Mo; 26304-A:S3Ni1Mo; 26304-B:(SUN2M2)
EN - As Welded 26304-A: S 62 6 FB S3Ni1Mo (AC)
Wire OK Autrod 13.40
AWS - As Welded A5.23: F8A15-ENi3-Ni3
AWS - PWHT A5.23: F8P15-ENi3-Ni3
AWS/EN A5.23:ENi3/ 14171-A:S2Ni3
EN - As Welded 14171-A: S 46 8 FB S2Ni3
Wire OK Autrod 13.49
AWS - PWHT A5.23: F8P2-EB2R-B2
AWS/EN A5.23:EB2R/ 24598-A:S S CrMo1
Wire OK Autrod 13.10 SC
AWS - As Welded A5.23: F9A8-EA3-A3
AWS - PWHT A5.23: F9P8-EA3-A3
AWS/EN A5.23:EA3/ 24598-B:SU 4M3
Wire OK Autrod 12.44
AWS - PWHT A5.23: F8P2-EB3R-B3
AWS/EN A5.23:EB3R/ 24598-A:S S CrMo2
Wire OK Autrod 13.20 SC
AWS - As Welded A5.23: F9A8-EG-G
AWS/EN A5.23:EG/ 26304-A:S3Ni1,5CrMo
EN - As Welded 26304-A: S 62 5 FB S3Ni1,5CrMo
Wire OK Autrod 13.44
Wire OK Tubrod 15.27S

Classifications

Grade S A FB 1 55 AC H5
Name EN ISO 14174
Grade S A FB 1 55 AC H4 only BlockPac/moisture-protection
Name EN ISO 14174

Consumable Characteristics

Slag Type Fluoride-basic
Grain Size (met) 0.2-1.6 mm (10x65 mesh)
Diffusible Hydrogen max 5 ml H/100g weld metal (Redried flux); max 4 ml H/100g in BlockPac (moisture protection)
Density nom: 1.1 kg/dm3
Basicity Index nom: 3.2
Alloy Transfer No Silicon or Manganese alloying

Flux Consumption

Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 26 V
kg Flux / kg Wire DC+ (met) 0.7 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 30 V
kg Flux / kg Wire DC+ (met) 1.0 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 34 V
kg Flux / kg Wire DC+ (met) 1.3 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 38 V
kg Flux / kg Wire DC+ (met) 1.6 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 26 V
kg Flux / kg Wire AC (met) 0.6 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 30 V
kg Flux / kg Wire AC (met) 0.9 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 34 V
kg Flux / kg Wire AC (met) 1.2 kg
Amps 580 A
Dimensions Ø 4.0 mm
Travel speed 55 cm/min
Volts 38 V
kg Flux / kg Wire AC (met) 1.4 kg

Typical Mechanical Properties

Charpy V-Notch (met) 170 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 33 %
Tensile Strength (met) 500 MPa
Testing Condition 1
Wire OK Autrod 12.22
Yield Strength (met) 410 MPa
Charpy V-Notch (met) 160 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 33 %
Tensile Strength (met) 500 MPa
Testing Condition 1
Wire OK Autrod 12.22
Yield Strength (met) 410 MPa
Charpy V-Notch (met) 90 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 33 %
Tensile Strength (met) 500 MPa
Testing Condition 1
Wire OK Autrod 12.22
Yield Strength (met) 410 MPa
Charpy V-Notch (met) 70 J
Charpy V-Notch Testing Temp (met) -50 degC
Conditional Statement AWS DC+
Elongation 33 %
Tensile Strength (met) 500 MPa
Testing Condition 1
Wire OK Autrod 12.22
Yield Strength (met) 410 MPa
Charpy V-Notch (met) 35 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement AWS DC+
Elongation 33 %
Tensile Strength (met) 500 MPa
Testing Condition 1
Wire OK Autrod 12.22
Yield Strength (met) 410 MPa
Charpy V-Notch (met) 140 J
Charpy V-Notch Testing Temp (met) 20 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 580 MPa
Testing Condition 1
Wire OK Autrod 12.24
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 115 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 580 MPa
Testing Condition 1
Wire OK Autrod 12.24
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 580 MPa
Testing Condition 1
Wire OK Autrod 12.24
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 60 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 580 MPa
Testing Condition 1
Wire OK Autrod 12.24
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 45 J
Charpy V-Notch Testing Temp (met) -51 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 580 MPa
Testing Condition 1
Wire OK Autrod 12.24
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 175 J
Charpy V-Notch Testing Temp (met) 20 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 12.32
Yield Strength (met) 475 MPa
Charpy V-Notch (met) 150 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 12.32
Yield Strength (met) 475 MPa
Charpy V-Notch (met) 130 J
Charpy V-Notch Testing Temp (met) -30 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 12.32
Yield Strength (met) 475 MPa
Charpy V-Notch (met) 110 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 12.32
Yield Strength (met) 475 MPa
Charpy V-Notch (met) 70 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 12.32
Yield Strength (met) 475 MPa
Charpy V-Notch (met) 170 J
Charpy V-Notch Testing Temp (met) 20 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.34
Yield Strength (met) 540 MPa
Charpy V-Notch (met) 160 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.34
Yield Strength (met) 540 MPa
Charpy V-Notch (met) 140 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.34
Yield Strength (met) 540 MPa
Charpy V-Notch (met) 115 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.34
Yield Strength (met) 540 MPa
Charpy V-Notch (met) 45 J
Charpy V-Notch Testing Temp (met) -51 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.34
Yield Strength (met) 540 MPa
Charpy V-Notch (met) 140 J
Charpy V-Notch Testing Temp (met) 20 degC
Conditional Statement AWS DC+
Elongation 26 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.40
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 110 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 26 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.40
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 26 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.40
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 26 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.40
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 40 J
Charpy V-Notch Testing Temp (met) -51 degC
Conditional Statement AWS DC+
Elongation 26 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 12.40
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 105 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 27 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 12.44
Yield Strength (met) 600 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 27 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 12.44
Yield Strength (met) 600 MPa
Charpy V-Notch (met) 65 J
Charpy V-Notch Testing Temp (met) -50 degC
Conditional Statement AWS DC+
Elongation 27 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 12.44
Yield Strength (met) 600 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement AWS DC+
Elongation 27 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 12.44
Yield Strength (met) 600 MPa
Charpy V-Notch (met) 195 J
Charpy V-Notch Testing Temp (met) 20 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 13.21
Yield Strength (met) 470 MPa
Charpy V-Notch (met) 185 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 13.21
Yield Strength (met) 470 MPa
Charpy V-Notch (met) 160 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 13.21
Yield Strength (met) 470 MPa
Charpy V-Notch (met) 70 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 13.21
Yield Strength (met) 470 MPa
Charpy V-Notch (met) 60 J
Charpy V-Notch Testing Temp (met) -51 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 560 MPa
Testing Condition 1
Wire OK Autrod 13.21
Yield Strength (met) 470 MPa
Charpy V-Notch (met) 110 J
Charpy V-Notch Testing Temp (met) -50 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 13.24
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 70 J
Charpy V-Notch Testing Temp (met) -60 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 13.24
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -73 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 13.24
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 120 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 25 %
Tensile Strength (met) 620 MPa
Testing Condition 1
Wire OK Autrod 13.24
Yield Strength (met) 530 MPa
Charpy V-Notch (met) 140 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 570 MPa
Testing Condition 1
Wire OK Autrod 13.27
Yield Strength (met) 460 MPa
Charpy V-Notch (met) 110 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 570 MPa
Testing Condition 1
Wire OK Autrod 13.27
Yield Strength (met) 460 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -60 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 570 MPa
Testing Condition 1
Wire OK Autrod 13.27
Yield Strength (met) 460 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -73 degC
Conditional Statement AWS DC+
Elongation 28 %
Tensile Strength (met) 570 MPa
Testing Condition 1
Wire OK Autrod 13.27
Yield Strength (met) 460 MPa
Charpy V-Notch (met) 90 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 690 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 610 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -50 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 690 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 610 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement AWS DC+
Elongation 24 %
Tensile Strength (met) 690 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 610 MPa
Charpy V-Notch (met) 100 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement EN DC+
Elongation 23 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 620 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -50 degC
Conditional Statement EN DC+
Elongation 23 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 620 MPa
Charpy V-Notch (met) 60 J
Charpy V-Notch Testing Temp (met) -60 degC
Conditional Statement EN DC+
Elongation 23 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 620 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement EN DC+
Elongation 23 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.40
Yield Strength (met) 620 MPa
Charpy V-Notch (met) 100 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 21 %
Tensile Strength (met) 800 MPa
Testing Condition 1
Wire OK Autrod 13.43
Yield Strength (met) 700 MPa
Charpy V-Notch (met) 75 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 21 %
Tensile Strength (met) 800 MPa
Testing Condition 1
Wire OK Autrod 13.43
Yield Strength (met) 700 MPa
Charpy V-Notch (met) 65 J
Charpy V-Notch Testing Temp (met) -50 degC
Conditional Statement AWS DC+
Elongation 21 %
Tensile Strength (met) 800 MPa
Testing Condition 1
Wire OK Autrod 13.43
Yield Strength (met) 700 MPa
Charpy V-Notch (met) 50 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement AWS DC+
Elongation 21 %
Tensile Strength (met) 800 MPa
Testing Condition 1
Wire OK Autrod 13.43
Yield Strength (met) 700 MPa
Charpy V-Notch (met) 95 J
Charpy V-Notch Testing Temp (met) -70 degC
Conditional Statement AWS DC+
Elongation 27 %
Tensile Strength (met) 600 MPa
Testing Condition 1
Wire OK Autrod 13.49
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 40 J
Charpy V-Notch Testing Temp (met) -101 degC
Conditional Statement AWS DC+
Elongation 27 %
Tensile Strength (met) 600 MPa
Testing Condition 1
Wire OK Autrod 13.49
Yield Strength (met) 500 MPa
Charpy V-Notch (met) 95 J
Charpy V-Notch Testing Temp (met) 0 degC
Conditional Statement AWS DC+
Elongation 22 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.44
Yield Strength (met) 610 MPa
Charpy V-Notch (met) 80 J
Charpy V-Notch Testing Temp (met) -20 degC
Conditional Statement AWS DC+
Elongation 22 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.44
Yield Strength (met) 610 MPa
Charpy V-Notch (met) 55 J
Charpy V-Notch Testing Temp (met) -40 degC
Conditional Statement AWS DC+
Elongation 22 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.44
Yield Strength (met) 610 MPa
Charpy V-Notch (met) 40 J
Charpy V-Notch Testing Temp (met) -62 degC
Conditional Statement AWS DC+
Elongation 22 %
Tensile Strength (met) 700 MPa
Testing Condition 1
Wire OK Autrod 13.44
Yield Strength (met) 610 MPa
x
x
x

x

Loading..