Dual Shield T-5

ESAB

Dual Shield T-5

The following items have been added to your list


x

Dual Shield T-5 is a basic slag flux cored wire that produces crack resistant, highly ductile weld deposits. The small diameter wires, such as .045 & 1/16" diameters can be used out-of-position. The arc characteristics are globular but can be improved with the use of argon mixes. Dual Shield T-5 is recommended for medium to heavy fabrication of many mild steels where superior toughness and crack resistance are required. It is a good choice for mild steel or when being joined to quenched and tempered low alloy high strength steels. The weld metal analysis is similar to an E7018 or E7018-1 low hydrogen electrode.

BUY NOW


Industries

  • Civil Construction
  • Industrial and General Fabrication
  • Mobile Equipment
  • Railcars

Welding Process

  • FCAW (Flux Core)

Typical Weld Metal Analysis %

Typical Weld Metal Analysis %
C Mn P S Si
75% Ar - 25% CO2
0.066 % 1.45 % 0.007 % 0.013 % 0.52 %

Approvals

Society TUV
Approvals are based on factory location. Please contact ESAB for more information.

Typical Charpy V-Notch Properties

Impact Value Testing Temperature
130 J(96 ft-lb) -18 degC(0 degF)
110 J(81 ft-lb) -29 degC(-20 degF)
96 J(71 ft-lb) -40 degC(-40 degF)
80 J(59 ft-lb) -51 degC(-60 degF)
236 J(174 ft-lb) 2 hr 621 degC(1150 degF) -18 degC(0 degF)
178 J(131 ft-lb) 2 hr 621 degC(1150 degF) -29 degC(-20 degF)
140 J(103 ft-lb) 2 hr 621 degC(1150 degF) -40 degC(-40 degF)
126 J(93 ft-lb) 2 hr 621 degC(1150 degF) -51 degC(-60 degF)

Classifications

ASME SFA 5.36 :
ASME SFA 5.20 :
AWS A5.36 : E71T5-M21P6-CS1-H4
AWS A5.36 : E71T5-M21A6-CS1-H4
AWS A5.20 : E71T-5C-JH4/T-5M-JH4

Typical Tensile Properties

Condition Stress Relieved As Welded
Reduction in Area 76 % 71 %
Shielding Gas 75% Ar - 25% CO2 75% Ar - 25% CO2
Tensile Strength 500 MPa(74 ksi) 560 MPa(81 ksi)
Yield Strength 355 MPa(52 ksi) 460 MPa(68 ksi)
Elongation 34 % 31 %
Testing Time 2 hr
Testing Temperature 621 degC(1150 degF)

Recommended Welding Parameters

Current TTW Dist. Voltage Wire Diameter Wire Feed Speed
75% Ar - 25% CO2
140-190 A 19-25.4 mm(3/4-1 in.) 19-28 V 1.2 mm(.045 in.) 635-889 cm/min(250-350 in./min)
300 A 19-25.4 mm(3/4-1 in.) 32 V 1.2 mm(.045 in.) 1651 cm/min(650 in./min)
220-280 A 19-25.4 mm(3/4-1 in.) 29-30 V 1.6 mm(1/16 in.) 457-635 cm/min(180-250 in./min)
280-380 A 25.4-31.75 mm(1-1.25 in.) 31-32 V 1.6 mm(1/16 in.) 635-1016 cm/min(250-400 in./min)
240-300 A 19-25.4 mm(3/4-1 in.) 29-32 V 1.2 mm(.045 in.) 1143-1651 cm/min(450-650 in./min)

Deposition Data

Current Deposition Rate Diameter Efficiency (%) TTW Dist. Voltage Wire Feed Speed
75% Ar - 25% CO2
170 A 3.2 kg/h(7.0 lb/h) 1.2 mm(.045 in.) 96 % 19 mm(3/4 in.) 19 V 724 cm/min(285 in./min)
250 A 4.9 kg/h(10.8 lb/h) 1.2 mm(.045 in.) 91 % 25.4 mm(1 in.) 30 V 1191 cm/min(469 in./min)
300 A 6.4 kg/h(14.2 lb/h) 1.2 mm(.045 in.) 92 % 25.4 mm(1 in.) 32 V 1539 cm/min(606 in./min)
300 A 4.5 kg/h(9.8 lb/h) 1.6 mm(1/16 in.) 92 % 25.4 mm(1 in.) 30 V 574 cm/min(226 in./min)
400 A 7.3 kg/h(16.1 lb/h) 1.6 mm(1/16 in.) 92 % 25.4 mm(1 in.) 32 V 937 cm/min(369 in./min)