Fuel Specifications
PM - GST Operating Data - 2118700
Gas Pressure - Cutting Oxygen |
80-110 psig |
Gas Pressure - Propane/NatGas |
10-30 psig |
Total Oxygen Consumption |
2,080 cfh |
Total Propane/NaturalGas Consumption |
225-500 cfh |
PM - GST Operating Data - 2118701
Gas Pressure - Cutting Oxygen |
80-110 psig |
Gas Pressure - Propane/NatGas |
10-30 psig |
Total Oxygen Consumption |
1,640 cfh |
Total Propane/NaturalGas Consumption |
225-500 cfh |
PM - GST Operating Data - 2118702
Gas Pressure - Cutting Oxygen |
80-110 psig |
Gas Pressure - Propane/NatGas |
10-30 psig |
Total Oxygen Consumption |
1,260 cfh |
Total Propane/NaturalGas Consumption |
225-500 cfh |
PM-100/200 - 2118700
Gas Pressure - Cutting Oxygen |
85 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
1800 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-100/200 - 2118701
Gas Pressure - Cutting Oxygen |
85 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
1400 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-100/200 - 2118702
Gas Pressure - Cutting Oxygen |
85 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
1020 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-100/200 - 2118703
Gas Pressure - Cutting Oxygen |
135 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
3040 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-100/200 - 2118707
Gas Pressure - Cutting Oxygen |
190 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
2020 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-300 - 2228184
Gas Pressure - Cutting Oxygen |
50 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
4600 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-300 - 2228185
Gas Pressure - Cutting Oxygen |
80 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
3800 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
PM-300 - 2228186
Gas Pressure - Cutting Oxygen |
135 psig |
Gas Pressure - Preheat Oxygen |
10-20 psig |
Gas Pressure - Propane/NatGas |
4-6 psig |
Total Oxygen Consumption |
5200 cfh |
Total Propane/NaturalGas Consumption |
180-240 cfh |
Operating Specifications
PM - GST Operating Data - 2118700
Metal Thickness |
10 to 16 in. |
Stand Off |
4-6 in. |
PM - GST Operating Data - 2118701
Metal Thickness |
6 to 10 in. |
Stand Off |
4-6 in. |
PM - GST Operating Data - 2118702
Metal Thickness |
3 to 6 in. |
Stand Off |
4-6 in. |
PM-100/200 - 2118700
Metal Thickness |
10 to 20 in. |
Stand Off |
4-6 in. |
PM-100/200 - 2118701
Metal Thickness |
6 to 10 in. |
Stand Off |
4-6 in. |
PM-100/200 - 2118702
Metal Thickness |
3 to 6 in. |
Stand Off |
4-6 in. |
PM-100/200 - 2118703
Metal Thickness |
20 to 30 in. |
Stand Off |
4-6 in. |
PM-100/200 - 2118707
Metal Thickness |
6 to 10 in. |
Stand Off |
4-6 in. |
PM-300 - 2228184
Metal Thickness |
20 to 30 in. |
Stand Off |
5-7 in. |
PM-300 - 2228185
Metal Thickness |
20 to 30 in. |
Stand Off |
5-7 in. |
PM-300 - 2228186
Metal Thickness |
30 to 40 in. |
Stand Off |
5-7 in. |
Tip Specifications
Fits PM-100, 200, & GST Torches
Metal Thickness |
3 to 6 in. |
Metal Thickness |
6 to 10 in. |
Metal Thickness |
6 to 10 in. |
Metal Thickness |
10 to 16 in. |
Metal Thickness |
10 to 24 in. |
Metal Thickness |
4 to 9 in. |
Fits PM-300 Torches
Metal Thickness |
20 to 30 in. |
Metal Thickness |
30 to 40 in. |
Extra Information
Oxygen pressure: Set while cutting lever is depressed; pressure measured at the torch.
Natural gas or propane pressure: Set while cutting lever is depressed and fuel gas valve is wide open; pressure measured at the torch.