Previous Next

ESAB

DUAL SHIELD II 110

DUAL SHIELD II 110

Dual Shield II 110 is an all-position flux cored electrode which produces a smooth spray-like transfer, low spatter levels, low diffusible hydrogen levels, easy slag removal and good arc direction. Dual Shield II 110 was designed to join high strength steel such as HY-100 and T-1 (25.4) in the as welded or stress relieved condition using 75% Ar / 25% CO2 shielding gas. It is well suited for joining high tensile steels that will be used in low temperatures. The weld metal analysis is similar to an E11018-M low hydrogen electrode.

Add to shopping list


Industries

  • Industrial and General Fabrication
  • Mobile Equipment

Welding Process

  • Welding-FCAW - Flux Core Arc Welding

Specifications


Typical Tensile Properties

75% Ar - 25% CO2
Condition Elongation Reduction in Area Stress Relieved Temperature Stress Relieved Testing Time Tensile Strength Yield Strength
Stress Relieved 19 % 54 % 1150 °F 8 hr 116 ksi 108 ksi
As Welded 19 % 54 % - - 120 ksi 110 ksi

Typical Charpy V-Notch Properties

75% Ar - 25% CO2
Condition Impact Value Stress Relieved Testing Temp Stress Relieved Testing Time Testing Temperature
Stress Relieved 29 ft-lb 1150 °F 8 hr 0 °F
Stress Relieved 27 ft-lb 1150 °F 8 hr -20 °F
Stress Relieved 21 ft-lb 1150 °F 8 hr -60 °F
As Welded 40 ft-lb - - 0 °F
As Welded 36 ft-lb - - -20 °F
As Welded 26 ft-lb - - -60 °F

Typical Weld Metal Analysis %

75% Ar - 25% CO2
PMnMoCSSiNi
0.013 %1.91 %0.39 %0.05 %0.01 %0.43 %1.74 %

Approvals: CWB, CSA W48 E761T1-K3M-H4, ABS
Classifications: ASME SFA 5.36, ASME SFA 5.29, AWS A5.36, E111T1-M21A4-K3-H4, AWS A5.29, E111T1-K3M-H4

Approvals are based on factory location. Please contact ESAB for more information.