Previous Next

DUAL SHIELD 7100 ULTRA

DUAL SHIELD 7100 ULTRA

How to order


Specifications


Classifications: ASME SFA 5.36, ASME SFA 5.20, AWS A5.20, E71T-9C-DH8, AWS A5.20, E71T-1M-DH8, AWS A5.36, E71T1-M21-CS1-DH8, AWS A5.36, E71T1-C1A2-CS1-DH8, AWS A5.20, E71T-1C-DH8, AWS A5.20, E71T-9M-DH8
Approvals: BV, DNV-GL, LR, ABS, CWB, CSA W48; E491T-9-H8

Approvals are based on factory location. Please contact ESAB for more information.


Alloy Type: C Mn
Welding Current: DC+

Typical Weld Metal Analysis %

PSCSiMn
100% CO2
0.010 %0.013 %0.02 %0.5 %1.3 %
weld metal analysis
0.010 %0.013 %0.02 %0.5 %1.3 %
75% Ar - 25% CO2
0.010 %0.012 %0.03 %0.6 %1.6 %

Typical Charpy V-Notch Properties

Condition Impact Value Testing Temperature
75% Ar - 25% CO2
As Welded 42 ft-lb 0 °F
As Welded 35 ft-lb -20 °F
100% CO2
As Welded 43 ft-lb 0 °F
As Welded 25 ft-lb -20 °F

Typical Tensile Properties

Condition Elongation Tensile Strength Yield Strength
100% CO2
As Welded 26 % 85 ksi 75 ksi
75% Ar - 25% CO2
As Welded 26 % 88 ksi 78 ksi

View full specs

Like many other Dual Shield products, Dual Shield 7100 Ultra operates in a wider parameter range and generates less welding fumes than many similar welding wires. The low spatter levels and easy slag removal minimizes post weld cleanup. Dual Shield 7100 Ultra can be used with either 100% CO2 or 75% Ar/25% CO2. This versatility in gas selection provides the fabricator greater flexibility in choosing both wire and gas. Applications include railcar and earth moving equipment, as well as general structural steel fabrication.

Add to shopping list


Industries

  • Automotive
  • Bridge Construction
  • Civil Construction
  • Industrial and General Fabrication
  • Mobile Equipment
  • Process
  • Railcars
  • Ship/Barge Building

Welding Process

  • Welding-FCAW - Flux Core Arc Welding

Specifications


Classifications: ASME SFA 5.36, ASME SFA 5.20, AWS A5.20, E71T-9C-DH8, AWS A5.20, E71T-1M-DH8, AWS A5.36, E71T1-M21-CS1-DH8, AWS A5.36, E71T1-C1A2-CS1-DH8, AWS A5.20, E71T-1C-DH8, AWS A5.20, E71T-9M-DH8
Approvals: BV, DNV-GL, LR, ABS, CWB, CSA W48; E491T-9-H8

Approvals are based on factory location. Please contact ESAB for more information.


Alloy Type: C Mn
Welding Current: DC+

Typical Weld Metal Analysis %

PSCSiMn
100% CO2
0.010 %0.013 %0.02 %0.5 %1.3 %
weld metal analysis
0.010 %0.013 %0.02 %0.5 %1.3 %
75% Ar - 25% CO2
0.010 %0.012 %0.03 %0.6 %1.6 %

Typical Charpy V-Notch Properties

Condition Impact Value Testing Temperature
75% Ar - 25% CO2
As Welded 42 ft-lb 0 °F
As Welded 35 ft-lb -20 °F
100% CO2
As Welded 43 ft-lb 0 °F
As Welded 25 ft-lb -20 °F

Typical Tensile Properties

Condition Elongation Tensile Strength Yield Strength
100% CO2
As Welded 26 % 85 ksi 75 ksi
75% Ar - 25% CO2
As Welded 26 % 88 ksi 78 ksi

x

Inquire about the DUAL SHIELD 7100 ULTRA



×

Find the Closest Distributor

x

Find the Closest Distributor

x

x

Loading..