Transfer
Equipment
Power
Supply
Shielding
Gases
Wire
Electrodes
Safety
Welding
Techniques
Welding
Conditions
Economics
Weld
Defects
Mig Spot
Welding
Tables

 

 

3 Table 5-2 – Mild Steel and Low  Alloy Steel Wires  Mechanical Property Requirements* YIELD SPOOLARC STRENGTH DESIG- SHIELDING CURRENT & TENSILE @ 0.2%   ELONG. IN MINIMUM ”V” AWS CLASS NATION GAS POLARITY STRENGTH OFFSET 2” MIN.% NOTCH IMPACT MIN. PSI MIN. PSI (MPa) (MPa) ER70S-2 65 Al 1.5% O2 1 70,000 58,000 22 20 ft.-lbs. @-200F CO2 DCEP (480) (480) (27J @-290C) ER70S-3 82 Ar 1.5% O2 1 DCEP 70,000 58,000 22 20 ft.-lbs. @O0F CO2 (480) (480) (27J @-180C) ER70S-4 85 CO2 1 DCEP 70,000 58,000 22 NOT REQUIRED (480) (480) ER70S-5 CO2 1 DCEP 70,000 58,000 22 NOT REQUIRED (480) (480) ER70S-6 86 CO2 1 DCEP 70,000 58,000 22 20 ft.-lbs. @-200F (480)   (480) (27J @-290C) ER70S-7 87HP CO2 1 DCEP 70,000 58,000 22 20 ft.-lbs. @-200F (480) (480) (27J @-290C) ER80S-D2 83 or Hi84 CO2 1 DCEP 70,000 58,000 17 20 ft.-lbs. @-200F (480) (480) (27J @-290C) ER70S-G NOT SPEC. NOT SPEC. 70,000 58,000 22 NOT REQUIRED (480) (480) 1Ar-CO2 can be used for all wires. *AWS A5.18-69