16
Important
Info
Cast Iron
Alloys
Tool Steel
Electrodes
Nickel
Alloys
Nickel
Silver
Alloys
Copper
Alloys
Aluminum
Alloys
Silver
Alloys
Steel
Alloys
Metal
Removal
Electrodes
Hardfacing
Alloys
Misc.
Alloys
Packaged
Products
All-State
Fluxes
Safety
Appendices
Procedures Clean joint area. Preheating to 600°F (316°C) is recommended to decrease stresses and increase strength and ductility. Use stringer beads or narrow weave beads. When more than one pass is required, the slag must be removed between passes. Do not let the part cool between passes but maintain a constant temperature. Each pass should be peened to help decrease stresses. Diameters and Recommended Amperages 3/32" (2.4mm)—50-90      5/32" (4.0mm)—110-150   1/8" (3.2mm)—80-120    3/16" (4.8mm)—130-170 Identification All-State® 8-60 printed on electrode coating and package. Packaging 3/32" (2.4mm) x 9" (225mm) in 5-lb. (2.27 kg) containers. Other sizes in 5-lb. (2.27 kg) and 10-lb. (4.54 kg) containers.